G·02 / Guide

What a wine cellar actually needs from its cooling system

Temperature is only one of four variables. Humidity, vibration and light decide whether a collection ages well or just gets cold.

Cellar cooling is often bought as if it were air conditioning with a different set point. It is not. A comfort unit is designed to cycle on and off around a room temperature, remove moisture and run for a few hours a day. A cellar needs the opposite: long, steady running at a low band, with humidity held rather than stripped.

Stability beats a lower number

Wine at a steady 15 °C ages more predictably than wine that swings between 10 and 20 °C every day. The swing causes expansion and contraction in the cork and accelerates the reactions that flatten a wine.

We aim for a band of about ±1 °C, which means the plant must be sized to hold the room at its hottest day, not its average.

Humidity is the part people forget

Too dry and corks shrink, letting air in. Too humid and labels and cartons suffer. A cellar wants roughly 55 to 75 percent relative humidity, which is a different control problem from cooling.

Comfort air conditioning removes moisture as a by-product. Cellar units are built to hold humidity, which is one reason they cost more than the comparable comfort unit.

Insulation and vapour barriers come first

A former storeroom against a hot north wall will fight any unit. Insulation, a sealed vapour barrier and a well-fitting door do more for stability than another kilowatt of cooling.

If the walls sweat in summer, the problem is usually the barrier rather than the plant, and no amount of refrigeration will fix it.

Keep the plant out of the room

Compressors vibrate and grilles blow air. Through-wall cellar units are compact and effective, but a remote split with the condenser outside and the evaporator ducted keeps noise and vibration away from the bottles and the tasting table.

Whatever the arrangement, the plant needs service access. A cellar unit boxed in behind racking is a future callout with a dismantling charge attached.

Short version

  • Target 12 – 14 °C with ±1 °C stability
  • Hold 55 – 75 % relative humidity
  • Insulate and seal before you upsize the plant
  • Leave service access to the unit

Tell us what the room is doing.