05 / Answers
What is it actually doing?
Fourteen faults we are called to most often in Tamboerskloof, each with the checks you can run yourself and the point at which it becomes our job.
Comfort cooling
The air conditioner runs but the room stays warm
Air moves, the unit hums, nothing gets cold. This is the most common callout we take, and it narrows to five faults in most Tamboerskloof homes.
Read the diagnosisIce forms on the indoor unit or the copper pipes
Ice on a cooling system is never normal. It means the coil is running below freezing, and the cause is almost always airflow or charge, not the thermostat.
Read the diagnosisThe air conditioner trips the breaker or the earth leakage
A trip is a protection device doing its job. Resetting it repeatedly can turn a cheap repair into a compressor replacement, so the fault needs finding rather than clearing.
Read the diagnosisWater drips from the indoor unit
Condensate has to leave the unit. When it comes out of the casing instead, the drain, the pump or a frozen coil is usually to blame, and the damage is to plaster and joinery.
Read the diagnosisThe air conditioner smells musty or sour
A smell is a growth problem, not a fragrance problem. Damp dust on the coil, pan and blower wheel feeds mould, and the unit then distributes spores through the room.
Read the diagnosisThe air conditioner rattles, hums or clunks
Noise has a source: a loose panel, a worn bearing, a vibrating pipe or a condenser mounted where it amplifies through a wall. Each sounds different and each is fixable.
Read the diagnosisRefrigeration
The fridge compartment is warm while the freezer still freezes
One compartment working and the other not tells you a lot: the compressor and most of the circuit are fine, and the fault sits in air transfer, defrost or control.
Read the diagnosisBoth fridge and freezer have gone warm
When both compartments fail together, the shared parts are suspect: power, compressor, start components or a loss of refrigerant. This is the one to act on quickly.
Read the diagnosisIce builds up inside the fridge or freezer
Frost on a frost-free appliance means the defrost system has stopped working. The ice is the symptom; the timer, element, sensor or drain is the cause.
Read the diagnosisThe cold room will not hold temperature
A walk-in drifting a few degrees is a serious signal: product life shortens before anyone notices, and the fault is often found in the defrost, the door or the condenser.
Read the diagnosisIce on the cold room floor or ceiling
Ice inside a walk-in is a defrost and drainage problem, and it becomes a safety problem the moment a staff member carries a full tray across it.
Read the diagnosisThe ice machine runs but produces little or no ice
Ice machines fail in a predictable order: water first, then scale, then the refrigeration circuit. Most calls are solved by water filtration and a proper descale.
Read the diagnosisCellar & wine
Pool heating
Not on the list?
Describe the noise, the temperature or the smell and we will tell you what it usually means, without a callout charge for the question.