The air conditioner runs but the room stays warm

Air moves, the unit hums, nothing gets cold. This is the most common callout we take, and it narrows to five faults in most Tamboerskloof homes.

What it usually is

  1. 01Filters or the indoor coil are clogged, so air bypasses the coil and arrives warm
  2. 02The system has lost refrigerant through a slow leak at a flare or braze joint
  3. 03The outdoor unit's fan or compressor has failed, often a capacitor or contactor
  4. 04A temperature sensor or control board is reading the room wrongly
  5. 05The condenser is boxed in, recirculating its own hot air

How to narrow it down

Check the basics first

Confirm the remote is in cooling, not fan or dry, and that the set point is at least 4 °C below the room temperature. On a ducted system, check the zone controller has the room you are standing in switched on. A surprising number of callouts end here.

Read the air at the grille

With the unit running, hold a thermometer at the supply grille and again at the return. A healthy split system delivers air roughly 8 to 12 °C colder than the room. If the split is only 3 or 4 °C, the system is running but not transferring heat, which points to airflow or charge rather than the compressor.

Look at the outdoor unit

Listen for the fan and the compressor. A fan that spins but no compressor hum, or a compressor that starts and trips within seconds, is an electrical fault rather than a gas one. Check the condenser is not choked with leaves or hemmed in by a screen, and that hot air is not bouncing back into the coil.

When to call

Call once the filters are clean and the unit still delivers warm air, or immediately if you see ice, hear a hard start and trip, or smell burning. Repeated tripping is an electrical fault and should not be reset repeatedly.