S·03 / Comfort cooling
The air conditioner trips the breaker or the earth leakage
A trip is a protection device doing its job. Resetting it repeatedly can turn a cheap repair into a compressor replacement, so the fault needs finding rather than clearing.
What it usually is
- 01A failing compressor, often with a seized or shorted winding
- 02A weak start or run capacitor drawing excessive current
- 03Water ingress into the outdoor isolator or wiring enclosure
- 04A damaged cable, rodent damage or a loose terminal heating up
- 05An earth leakage trip from moisture in the indoor unit or a damaged heater element
How to narrow it down
Separate the two kinds of trip
A circuit breaker trip is an overload or short. An earth leakage trip is current escaping to earth, usually water or insulation. Note which device moved: the two lead to completely different tests, and a photo of the distribution board saves a conversation.
Stop resetting it
If the breaker trips again within seconds of restart, leave it down and isolate the unit at its own isolator. A compressor attempting to start against a fault draws locked-rotor current, which is exactly what damages windings beyond repair.
Look for water and heat
Check for damp around the outdoor isolator, staining on the indoor unit's casing, and any warm or discoloured plug or terminal. In older Tamboerskloof houses, outdoor units on north walls take a lot of sun and rain, and enclosure seals fail quietly.
When to call
Call before resetting a third time. Trips caused by insulation or compressor faults get worse with each attempt, and an earth leakage trip on a circuit shared with other equipment should be treated as urgent.
Before you book.
Still not sure?
Describe what it is doing and we will tell you whether it needs a visit this week or can wait.