S·08 / Refrigeration

Both fridge and freezer have gone warm

When both compartments fail together, the shared parts are suspect: power, compressor, start components or a loss of refrigerant. This is the one to act on quickly.

What it usually is

  1. 01No power at the socket, or a tripped circuit supplying the appliance
  2. 02A failed start relay or capacitor leaving the compressor unable to run
  3. 03A compressor that has failed electrically or mechanically
  4. 04A refrigerant leak that has emptied the circuit over time
  5. 05A control board fault on a modern appliance with electronic control

How to narrow it down

Confirm power and listen

Test the socket with a lamp or phone charger, and check the plug and cord for heat damage. Then listen at the back: a hum that stops after a few seconds, repeated every minute or two, is a compressor trying and failing to start.

Feel the back and sides

A running fridge has a warm grid or side panels where heat is rejected. If the cabinet is stone cold everywhere and there is no compressor hum, the compressor is not running at all. If the sides are hot but the interior is warm, the circuit is running but not cooling.

Note the appliance details

Photograph the data plate and the model number before calling. Age, refrigerant type and control type decide whether a repair makes sense, and it saves a return visit.

When to call

Call the same day. A domestic fridge holding food at room temperature is a food-safety issue, and a commercial unit is a trading issue. We keep space in the week for breakdowns and will tell you honestly if the appliance is beyond economic repair.

S·08 / QuestionsAnswers

Before you book.

Still not sure?

Describe what it is doing and we will tell you whether it needs a visit this week or can wait.

CallWhatsAppGet a quote