The fridge compartment is warm while the freezer still freezes
One compartment working and the other not tells you a lot: the compressor and most of the circuit are fine, and the fault sits in air transfer, defrost or control.
What it usually is
- 01A failed evaporator fan so cold air never reaches the fridge section
- 02An iced-up evaporator from a defrost fault blocking the air path
- 03A blocked air channel between freezer and fridge
- 04A faulty damper or thermostat controlling the fridge compartment
- 05Overloading or a door seal failure letting warm air in faster than the unit can remove it
How to narrow it down
Empty and inspect
Move perishables to a cooler or another fridge and look at the back wall of the freezer. A solid block of ice behind a cover panel points to defrost. A clean freezer with a silent fan points to airflow.
Listen for the fan
Open the freezer door and press the door switch, or simply listen when the compressor runs. You should hear air moving. Silence with a running compressor means the evaporator fan has stopped, and that is a repairable part rather than a new appliance.
Check seals and loading
Close a sheet of paper in the door at several points: if it slides out easily, the gasket is not sealing. Overfilling in front of the air outlets causes the same warm-fridge symptom without any fault at all.
When to call
Call once the appliance is defrosted, empty and still not holding temperature in the fridge section. Defrost and fan faults are routine repairs, and food loss is the expensive part if it is left running for days.