S·14 / Pool heating

The pool heat pump runs but the water stays cold

Heat pumps heat slowly and lose heat fast. Before suspecting the machine, check flow, cover and air temperature, which account for most disappointing pools.

What it usually is

  1. 01Insufficient water flow through the unit from a dirty filter or a valve left part-closed
  2. 02No pool cover, so heat leaves overnight as fast as it arrives
  3. 03Air temperature too low for the model's operating range
  4. 04A frosted or dirty evaporator restricting heat absorption
  5. 05A refrigerant, compressor or controller fault

How to narrow it down

Check flow and filtration

Feel the water leaving the heat pump: it should be noticeably warmer than the pool. Clean the filter, confirm the bypass valve is set for full flow through the unit, and check the pressure gauge. Low flow is the most common cause of poor heating and the easiest to fix.

Cover the pool

An uncovered pool in Tamboerskloof loses most of its heat overnight, especially on a windy evening. A cover changes the numbers more than any setting on the machine.

Read the machine

Look at the display for a fault code, listen for the fan and compressor, and check the evaporator for frost or leaves. A unit that ices up in mild weather has a refrigerant or airflow problem, not a thermostat setting.

When to call

Call if the outlet water is not warmer than the pool, if the unit ices or trips, or if it runs continuously without reaching set point. Heat pumps are repairable, and a service before summer is cheaper than a failure in December.